NETWORK ENERGY

Monitor, Control and Protection

Know the status, and availability of your network and infrastructure power systems. Implement automated or manual control processes. 

Make informed decisions and take control. 

NETWORK ENERGY, CONTROL & PROTECTION SOLUTIONS

Centrally monitor, control and protect your network and critical energy usage and requirements with our extensive range of built-for-purpose devices, sensors,timers and software. 

ENERGY & LOAD MANAGEMENT

iCE multi-function energy meters offer remote monitoring and status indications of all AC and DC powered infrastructure, devices and equipment.

iCE ROGOWSKI COILS

Rogowski coils consist of a helical coil of wire in a flexible sheath. Because of their design and flexibility are the ultimate alternative to rigid CT's. No additional integrator circuits are required when used with iCE energy meters

CONTROL AND AUTOMATION

iCE offer a comprehensive range of relays, timers and contactors for remote, automated and manual control. 

REMOTE GENERATOR MONITORING

Intelligent Uninterruptible Power Distribution - Rack and/or tower mounted UPS solutions with remote monitoring options.

UPS MONITORING SOLUTIONS

Power presence, load, available battery run-time and fault alerts are all key indicators that can be remotely

monitored on a UPS system. 

METERED RACK POWER DISTRIBUTION

Remotely monitor and control the power of your mount devices - Convert passive PDU's or install intelligent iPDU's with remote monitoring with optional socket/port switching options.

Rack device, power management solutions

iCE offer a comprehensive range of metered and managed PDU's. These include options on capacity, load, control, colour and external sensor options.  

A Series:

Active metering of complete iPDU unit.
 

B Series:

Active metering of individual outlet ports.
 

C Series:

Active metering of complete iPDU unit with individual outlet control (outlet/port switching options)
 

D Series:

Active metering and control of overall unit and all individual outlets/ports

ATS Series:

Automated Transfer Switch options available for rack devices with remote management options.

METERING 

  • Total current load

  • Outlet current load (B, D Series)

  • Input voltage

  • Total energy consumption - kWh

  • Outlet energy consumption - kWh (B, D Series)

  • Total power consumption - kW

  • Outlet power consumption - kW (B, D Series)

  • Power factor

  • On/Off State of each outlet (C, D Series)

  • Temperature/Humidity, door, smoke, leak sensor options

 

Capacity & Outlet

Options

 

OUTLET OPTIONS

Outlet Quantity - Standard

  • 12  - 8XC13 plus 4XC19 - 19' Rack Mount

  • 24 - 21XC13 plus 3XC19 - 0U Vertical Mount

Outlet Quantity - Pre-Order

  • A Series: 8-48 Outlets

  • B Series: 8-36 Outlets

  • C Series: 8-36 Outlets

  • D Series: 8-36 Outlets

INPUT POWER OPTIONS

Rated Input voltage

  • Single Phase - 230VAC

  • Three Phase - 380VAC

Load current options

  • 16Amp

  • 32Amp

  • 3X16Amp

  • 3X32Amp

Colour Options

  • Black (default)

  • Blue

  • Red

  • Yellow

  • Green

  • Others on request (cost/lead time implications)

New and custom models are introduced on a regular basis. The Images shown are for reference only and may not reflect the model required or purchased. 

Remote Generator Monitoring

Remotely monitor your generator status with real-time "variable" sensors:

Enhance the traditional digital "low-level" alerts with analogue real-value sensors offing useful  information on actual fuel levels, estimated run-time and health.

Prevent generator failure with actual temperature values and oil pressure readings.

Fuel Levels:

View actual fuel level in liters or percentage.
 

Water Temperature:

Prevent overheating with actual water temperature in degrees celsius.
 

Magnetic Fuel Level Sensor

iCE LoRa (IoT) Module

Oil Pressure:

Prevent overheating with actual water temperature in degrees celsius.
 

Current (Amps):

Show actual load on the generator when running.
 

Security:

Monitor access and intrusion to prevent battery and fuel theft.
 

Oil Pressure Sensor

Communication & Connectivity:

Multiple options are available to ensure connectivity and readings from your generator. These include:

 

  • Ethernet (Copper or Fiber)

  • Wifi (Wireless)

  • LoRa (IoT)

 

4-20mA Power Loop Method:

Sensors are wired and powered by the standards based 4-20mA loop relative to ground.

 

Realist 3D Views of the generator, environments, sensors and analytics

 

ABOUT US

iCE-Intelligent Controlled Environments, specialize in unmanned monitoring of critical environments, equipment or devices.

Established in 2007, iCE has grown with the demand for more intelligent environments to ensure optimal conditions, stability and security.

PARTNERS

Through its global technical and manufacturing partners, iCE is able to keep on-top of emerging technologies and trends.

 

As a result, iCE solutions are highly scable and can accomodate almost any environment or requirment. 

SEND US AN EMAIL

  • Grey Facebook Icon

Follow us on Facebook

CONTACT INFO

17 Scott Street, Waverly, Johannesburg, Gauteng

2 Friars Grange, 8 Porterfield Rd , Blouberg, Western Cape

© 2020 iCE-INTELLIGENT CONTROLLED ENVIRONMENTS (Pty) Ltd